Table 9.1. Error Codes (Operational)
| Value | Description |
|---|---|
| 6101 | This symbology is not supported by the current version of Morovia Barcode DLL. |
| 6102 | The message is either empty or contains invalid character for the chosen symbology. |
| 6103 | The measurement unit must be either English (0) or Metric (1). |
| 6104 | The Zoom Ratio should ranged between 0.1 and 100 |
| 6105 | The NarrowToWideRatio should be between 2.0 and 3.0 |
| 6107 | Failed to overwrite file or create the new file. It may be caused by insufficient privilege or disk is full. |
| 6108 | Invalid Raster Image Resolution. The resolution must be greater than 50. |
| 6109 | The label size you specified is invalid, or you can not edit the size under the current mode. |
| 6112 | The current symbology required fixed length. The length you specified does not meet this requirement. |
| 6113 | The message string contains characters that can not be encoded under the current symbology. |
| 6114 | The object can not be loaded from the media specified. See Error Log for details. |
| 6115 | The object failed to save itself to the specified media. |
| 6116 | Invalid value for BarHeight property. |
| 6117 | The MaxicodeZipCode property must consist a valid zip code with up to 6 alpha-numeric characters. |
| 6118 | The MaxicodeCountryCode must between 000 and 999 |
| 6119 | The value range for MaxicodeMode must be between 2 and 6. |
| 6120 | The value range for MaxicodeClass must be between 000 and 999. |
| 6121 | Error happens during the PDF417 encoding process. For more information retrieve the Error object. |
| 6122 | Can not generate bitmap handle. Possible reasons include insufficient memory, too big size of the bitmap etc. |
Table 9.2. Error Codes (Encoding)
| Value | Description |
|---|---|
| 10 | The AI portion of an EAN-128 structure must be numeric. (EAN-128) |
| 11 | The data portion of the EAN-128 data must be alpha-numeric. (EAN-128) |
| 12 | Invalid UCC/EAN-128 structure. Check whether the AI and field ID are enclosed with parenthesis. (EAN-128) |
| 13 | The length of the data portion of the EAN-128 is incorrect. (EAN-128) |
| 14 | Based on the AI, the data portion must be numeric. However, this is not the case in the message encoded. (EAN-128) |
| 20 | No control block was found in the message. (PDF417) |
| 21 | Invalid Raster Image Resolution. The resolution must be greater than 50. |
| 22 | Error in the segment index. Either the segment index is not numeric, or the index is bigger than the total segment count. (PDF417) |
| 23 | Error in total segment count field. (PDF417) |
| 24 | Incorrect MacroPDF417 optional field format. (PDF417) |
| 30 | The size required is too small to hold the data. (PDF417, Data Matrix) |
| 40 | GLI must be 6 digits in the range between 0 and 811,799. (PDF417) |
| 41 | The security level is too high to encode all the data. (PDF417) |
| 50 | A required structural append field is missing. (Data Matrix Structural Append) |
| 51 | No control block was found in the message. (Data Matrix Structural Append) |
| 52 | Error in the sequence indicator field. Either it is not numeric, or the value is out of range. (Data Matrix Structural Append) |
| 53 | Error in the total number of total symbols field. This field can only be a number between 1 and 16. (Data Matrix Structural Append) |
| 54 | Invalid file ID. Either it contains invalid characters, or the value is out of range. (Data Matrix Structural Append) |
| 60 | Error in the specified ECI. Either it contains invalid characters, or the value is out of range. (Data Matrix ECI) |
| 70 | Macro 05 or Macro 06 should appear at the first position of the input and should not be used in conjunction with structural append. (Data Matrix Macro) |
| 71 | Reader programming ~3 should appear at the first position of the input and should not be used in conjunction with structural append. (Data Matrix Reader Programming) |
| 200 | Carrier message prefix detected but not all required fields are present. (MaxiCode) |