7.2. Macro 5 and 6

Data matrix provides a way of abbreviating two industry specific header and trailer in one symbol character. This feature aims to reduce the overall symbol size. They must appear at the beginning of the input. You can use tilde codes ~5 and ~6 to enter them.

Table 7.1. Macro 5 and 6

Tilde Sequence Name Interpretation
    header trailer
~5 05 Macro [)>[RS]05[GS] [RS][EOT]
~6 06 Macro [)>[RS]06[GS] [RS][EOT]